N-004-DS-5L-FSUAQ Кабель оптический LazrSPEED 300, 4 волокна ОМ3, LSZH, внутренний, фут
Product Classification CommScope
Product Type Fiber indoor cable
- Standards And Qualifications
- EN50575 CPR Cable EuroClass
- Dca,s1a,d1,a1
- Cable Qualification Standards
- ANSI/ICEA S-83-596,Telcordia GR-409
Cable Type Distribution
- Construction Type
- Non-armored
- Subunit Type
- Gel-free
Fiber Type Solution
- OM3, LazrSPEED 300
- Total Fiber Count
- 24
- Fiber Type
- OM3, LazrSPEED 300
- Fiber Type, quantity
- 24
- Jacket Color
- Aqua
Dimensions
- Cable Weight
- 44.0 lb/kft,66.0 kg/km
- Diameter Over Jacket
- 8.60 mm,0.34 in
Physical Specifications
- Minimum Bend Radius, loaded
- 13.0 cm,5.1 in
- Minimum Bend Radius, unloaded
- 8.6 cm,3.4 in
- Tensile Load, long term, maximum
- 90 lbf,400 N
- Tensile Load, short term, maximum
- 300 lbf,1335 N
- Vertical Rise, maximum
- 500.0 m,1640.4 ft
Flame Test Specifications
- Flame Test Listing
- NEC OFNR-LS ETL and c ETL
- Flame Test Method
- IEC 60332-3,IEC 60754-2,IEC 61034-2,IEEE 383,UL 1666,UL 1685
Environmental Specifications
- Environmental Space
- Low Smoke Zero Halogen LSZH,Riser
- Installation Temperature
- -10 C to 60 C 14 F to 140 F
- Operating Temperature
- -20 C to 70 C -4 F to 158 F
- Storage Temperature
- -40 C to 70 C -40 F to 158 F
Mechanical Test Specifications
- Compression
- 10 N/mm,57 lb/in
- Compression Test Method
- FOTP-41,IEC 60794-1 E3
- Flex
- 100 cycles
- Flex Test Method
- FOTP-104,IEC 60794-1 E6
- Impact
- 4.34 ft lb,5.88 N-m
- Impact Test Method
- FOTP-25,IEC 60794-1 E4
- Strain
- See long and short term tensile loads
- Strain Test Method
- FOTP-33,IEC 60794-1 E1
- Twist
- 10 cycles
- Twist Test Method
- FOTP-85,IEC 60794-1 E7
Environmental Test Specifications
- Heat Age
- -20 C to 85 C -4 F to 185 F
- Heat Age Test Method
- IEC 60794-1 F9
- Low High Bend
- -10 C to 60 C 14 F to 140 F
- Low High Bend Test Method
- FOTP-37,IEC 60794-1 E11
- Temperature Cycle
- -20 C to 70 C -4 F to 158 F
- Temperature Cycle Test Method
- FOTP-3,IEC 60794-1 F1